
Aluplan ® | Flat roofs for premium all-aluminum cover solutions.
Any contour | Fit in circular, square or irregular shapes. Large span | Rangings from 3m to 80 m free span. Opretational access | Total or partially removable for maintenance operations. Low profile | Reducing air volume for odour treatment.

Alusphere ® | Dome roofs
Applications | Petroleum Potable Water Wastewater Bulk Storage Architectural structures Designed according to specific regulations (EUROCODE, AWWA, API 650, national codes, ..)

alusphere ® | Dome roofs for premium all-aluminum cover solutions.
Our aluminum dome alusphere® is buitl by a trianguled profile system, covered with triangular panels. Besides the advantages os the use structural aluminum, these covers: Allow large diameters: Its clear span design elemante the need for intermediate columns and reinforcement of thank walls, with spans above the 100m. Have operational flexibility: Allows the installation of accessories, like doors, hatches and conections. Designed according to specific regulations (EUROCODE, AWWA, API 650, national codes, ..)

AMETank
AMETank enables rapid configuration, design, and detailing of above-ground shop-built and field-erected storage tanks per API 650, EN 14015, API 653, API 620, AWWA D100, and AWWA D103. Elevated tanks, tanks with transitions, and double-wall cryogenic tanks designs are supported. Self-supported, structure with/without column supported cone/dome/umbrella roofs, and internal/external single/double-deck floating roofs can be designed and detailed. Plates thickness, structure selection and sizing, appurtenances sizing, seismic, wind, internal and external pressure calculations are supported. Design calculation reports can be generated. US and metric/SI materials, Inputs, reports, outputs, and drawings are supported. Interactive tank 3D layout enables complete design with fabrication detailing within two hours including production geometry, to-scale general-arrangement & fabrication drawings, weld maps, assembly, nesting, and CNC, Bill of Quantities, Bill of Materials, weight reports, welds reports, and cost calculations. Tank LIDAR 3D-Scan point-clouds can be imported for API 653 assessments including shell verticality & out-of-roundness, bottom elevation & settlement, column verticality, floating-roof gap analysis, as-built drawings, and calibration and strapping charts. Complete tank Finite Element Analysis (FEA) from mesh generation to stresses visualization in new and as-is condition based on 3D-scan LIDAR point-clouds per API 579 Level 3 Fitness for Service is included. Accessways including wind girders, roof walkways, spiral stairways, ladders, roof and shell platforms, bridges, and stairway towers are available. Agitators, heating-coils, and appurtenances with several options and styles, Generation of plates CNC drawings, weld maps, shell rollouts, and detailed assembly and component fabrication drawings for structure, appurtenances, accessways are supported. 3D models, drawings, BOQs, BOMs, weights, and cost data can be edited within AMETank or exported.

Amigo2

AMPHIBOT
Suitable for water treatment settling tanks, industrial process basins and agricultural lagoons .

AMPipeline & AMEPlant

AMPreVA

API 2350 Overfill Prevention Guideline and Checklist
The new, globally applicable version of the API 2350 standard is here. It provides a modern best practice in overfill prevention that can help protect your tank storage facility. The site www.api-2350.com, provides a great way to get all necessary information about API 2350, and to support you when implementing the standard. Download our "API 2350 guideline and checklist".

API couplings
Our quick couplers are meant to facilitate the connection with tank trucks and rail tanks. The ergonomic design eases their application and provides perfect sealing and rapidity of loading or unloading processes. The particular design perfected by OMC makes them handy, ergonomic and easy to use. The installation of the API RP 1004 dry-disconnect couplers is easy to perform and takes place by simply connecting the TTMA flange with which it is equipped with the relative counterpart installed on the loading arm or on the flexible hose.
API RP 1004 COUPLER (model 0513)
SILEA series 513 manual coupler is used in the petrochemical industry when a fast dry coupling is required, without product’s leakage between female coupler and male adaptor. It’s mainly used to connect a bottom loading arm or a hose to a tank truck equipped with a bottom loading adapter. The coupler is accordant to API RP 1004 spec and it can be used with every API RP adaptor. The SILEA 513 coupler grants the loading operation without spillage and totally safe condition to the operator. It complies with the European ATEX 94/9/CE and the PED 97/23/CE directives.

Architectural
Architectural | Aluminum covering of digesters A wide variety of shapes and configuration High engineering and precision level Corrosion resistant material Recyclable

ATD - AUTOMATIC TANK DEWATERING
ATD – DEWATERING Over time a water layer can form on the bottom of the storage tank containing hydrocarbon crudes. Due to this water, a possibility exists of increased corrosion. Therefore, this water will need to be periodically drained manually. By monitoring the drainage water, an operator can accurately measure the presence of hydrocarbons reducing the risk of contamination in high risk areas.

ATEX & IECEx approved MK 10 closed sampling system
Wherever there is a need to take accurate samples of liquid cargo on-board, without allowing the leakage of vapour during the process, the ATEX & IECEx approved MK10 closed sampling system offers an ideal solution.

ATEX & IECEx approved MK 14 closed sampling system
Practical, operator friendly and durable in service, the ATEX & IECEx approved MK 14 closed sampling system offers a cost effective solution to the problem of liquid sampling under closed conditions.
529 results found